Evaluation of Gamma-Ray Dose Distribution in the Toroidal Direction of LHD Vacuum Vessel from Radionuclides Generated in Deuterium Plasma Experiments

Author:

Ogino Yasuyuki12ORCID,Kobayashi Makoto I.34,Mukai Keisuke2,Yagi Juro2,Konishi Satoshi2,Ogawa Kunihiro34,Isobe Mitsutaka34

Affiliation:

1. Institute for Materials Research, Tohoku University, Sendai, Miyagi 980-8577, Japan

2. Institute of Advanced Energy, Kyoto University, Uji, 611-0011 Kyoto, Japan

3. National Institute of Fusion Science, National Institutes of National Sciences, Toki, 509-5292 Gifu, Japan

4. The Graduate University for Advanced Studies, SOKENDAI, Toki, 509-5292 Gifu, Japan

Abstract

The evaluation of activities from radionuclides inside a vacuum vessel is required for the safe maintenance and estimation of the activation level of fusion devices. The Large Helical Device (LHD), Toki, Japan, has been performing deuterium plasma experiments since 2017, and radionuclides have accumulated in components such as vacuum vessels. In this work, the gamma-ray spectrum and activity of each detected radionuclide in an LHD vacuum vessel were evaluated using portable high-purity germanium (P-HPGe) and numerical calculations of photon transport for comparison with the removed armor tiles to evaluate the occupational exposure in the maintenance of LHD experiments. Measurements using the P-HPGe detector were performed at 20 positions along the toroidal direction of the LHD, at each O port, and between each pair of adjacent O ports. Using the estimated efficiency of the photoelectronic effects inside the P-HPGe detector calculated by Monte Carlo N-particle code version 6.1, the activities of the radionuclides in the armor tiles attached to the vacuum vessel were evaluated. The estimated activity concentrations were compared with the measured activities of the armor tiles removed from the vacuum vessel. Gamma rays from 58Co, 54Mn, and 60Co were detected, and the measured activities of 58Co and 54Mn generated by fast neutrons in the armor tile were almost consistent with those obtained from the removed armor tiles. The radioactivity of 60Co in the armor tile was underestimated compared with the activity obtained from the removed armor tiles. The measurement of activation by fast neutrons is feasible, whereas activation by thermal neutrons requires more accurate calculations and surveys to be measured using this method.

Funder

NIFS Collaboration Research Program

Publisher

Hindawi Limited

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3