Dorsally Comminuted Fractures of the Distal End of the Radius: Osteosynthesis with Volar Fixed Angle Locking Plates

Author:

Gogna Paritosh1ORCID,Selhi Harpal Singh2,Singla Rohit1ORCID,Devgan Ashish1,Magu Narender Kumar1,Mahindra Pankaj2ORCID,Yamin Mohammad2

Affiliation:

1. Department of Orthopaedics and Rehabilitation, Pt. B.D. Sharma Post graduate Institute of Medical Sciences, 2/11-J Medical Enclave, PGIMS, Haryana, Rohtak 124001, India

2. Department of Orthopaedics, Dayanand Medical College and Hospital, Punjab, Ludhiana 141001, India

Abstract

Background. Dorsally comminuted distal radius fractures are unstable fractures and represent a treatment challenge. The objective of this study was to evaluate the functional and radiological outcome of dorsally comminuted fractures of the distal radius fixed with a volar locking plate. Patients and Methods. Thirty-three consecutive patients with dorsally comminuted fractures of the distal end of the radius were treated by open reduction and internal fixation with AO 2.4 mm (n=19)/3.5 mm (n=14) volar locking distal radius plate (Synthes, Switzerland, marketed by Synthes India Pvt. Ltd.). There were 7 type A3, 8 type C2, and 18 type C3 fractures. The patients were followed up at 6 weeks, 3 months, 6 months, and 1 year postoperatively. Subjective assessment was done as per Disabilities Arm, Shoulder, and Hand (DASH) questionnaire. Functional evaluation was done by measuring grip strength and range of motion around the wrist; the radiological determinants were radial angle, radial length, volar angle, and ulnar variance. The final assessment was done as per Demerit point system of Saito. Results. There were 23 males and 10 females with an average age of 44.12 ± 18.63 years (18–61 years). Clinicoradiological consolidation of the fracture was observed in all cases at a mean of 9.6 weeks (range 7–12 weeks). The average final extension was 58.15° ± 7.83°, flexion was 54.62° ± 11.23°, supination was 84.23° ± 6.02°, and pronation was 80.92° ± 5.54°. Demerit point system of Saito yielded excellent results in 79% (n=26), good in 18% (n=6), and fair in 3% (n=1) patients. Three patients had loss of reduction but none of the patients had tendon irritation or ruptures, implant failure, or nonunion at the end of an one-year followup. Conclusion. Volar locking plate fixation for dorsally comminuted distal radius fractures results in good to excellent functional outcomes despite a high incidence of loss of reduction and fracture collapse.

Publisher

Hindawi Limited

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3