Author:
Gui Xue-yang,Cheng Zhao-hui,Shi Hong-fei,Chen Yi-xin,Xiong Jin,Wang Jun-fei,Qiu Xu-sheng,Zhang Zi-tao
Abstract
Abstract
Background
Volar locking plating remains a popular method for the surgical management of distal radius fractures. Dorsal metaphyseal comminution (DMC) is a common fracture pattern which weakens the stability during fracture fixation. In this study, we aimed to compare the radiographic and functional outcome of the intra- and extra-articular distal radius fractures with DMC following single volar locking plate fixation.
Materials and methods
Patients suffered from a distal radius fracture with DMC were reviewed in the clinical database of the authors’ institution between Jan 2016 and Jan 2020. The included patients were classified into the extra-articular (A3) group or the intra-articular (C2 and C3) group according to the AO/OTA system. The radiological parameters, wrist range of motion, and functional outcomes were evaluated following open reduction and volar locking plate fixation.
Results
A total of 130 patients were included in this study with a mean follow-up length of 17.2 months. Compared with the A3 fracture group, no significant fracture re-displacement or reduced wrist ROMs was observed in the C2 fractures after 12-month’s follow-up. However, significantly decreased volar tilt (P = 0.003) as well as the extension/flexion ROMs were observed in the C3 fractures comparing to the A3 fractures. Most of the patients achieved an excellent (n = 75) or good (n = 51) Gartland and Werley wrist score. Four patients with C3 fractures resulted in a fair functional outcome due to a significant loss of volar tilt during follow-up.
Conclusions
The single volar locking plate fixation provided sufficient stability for distal radius fractures with DMC, and resulted in similar radiological and functional outcomes in the intra-articular distal radius fractures with a simple articular component (C2 fractures) as those in the extra-articular fractures. Considering the intra-articular fractures with multifragmentary articular component (C3 fracture), despite of the subsequent loss of volar tilt, the majority of the patients achieved good to excellent wrist function following single volar locking plating.
Trial registration
This study has been registered on the ClinicalTrials.gov.
Funder
National Natural Science Foundation of China
Six Talent Peeks Project in Jiangsu Province
Medical Science and technology development Foundation, Nanjing Department of Health
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Surgery
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献