Whole Prostate Volume and Shape Changes with the Use of an Inflatable and Flexible Endorectal Coil

Author:

Osman Murat12ORCID,Shebel Haytham3,Sankineni Sandeep1ORCID,Bernardo Marcelino L.14,Daar Dagane1,Wood Bradford J.5,Pinto Peter A.6,Choyke Peter L.1,Turkbey Baris1,Agarwal Harsh K.17

Affiliation:

1. Molecular Imaging Program, NCI, NIH, Bethesda, MD 20892, USA

2. George Washington University, Washington, DC 20052, USA

3. Department of Radiology, Nephrology Center, Mansoura University, Mansoura 35516, Egypt

4. Leidos Biomedical Research, Inc., Frederick National Laboratory for Cancer Research, Frederick, MD 21702, USA

5. Center for Interventional Oncology, NIH, Bethesda, MD 20892, USA

6. Urologic Oncology Branch, NCI, NIH, Bethesda, MD 20892, USA

7. Philips Research North America, Briarcliff Manor, NY 10510, USA

Abstract

Purpose.To determine to what extent an inflatable endorectal coil (ERC) affects whole prostate (WP) volume and shape during prostate MRI.Materials and Methods.79 consecutive patients underwent T2W MRI at 3T first with a 6-channel surface coil and then with the combination of a 16-channel surface coil and ERC in the same imaging session. WP volume was assessed by manually contouring the prostate in each T2W axial slice. PSA density was also calculated. The maximum anterior-posterior (AP), left-right (LR), and craniocaudal (CC) prostate dimensions were measured. Changes in WP prostate volume, PSA density, and prostate dimensions were then evaluated.Results.In 79 patients, use of an ERC yielded no significant change in whole prostate volume (0.6±5.7%,P=0.270) and PSA density (-0.2±5.6%,P=0.768). However, use of an ERC significantly decreased the AP dimension of the prostate by-8.6±7.8%(P<0.001), increased LR dimension by4.5±5.8%(P<0.001), and increased the CC dimension by8.8±6.9%(P<0.001).Conclusion.Use of an ERC in prostate MRI results in the shape deformation of the prostate gland with no significant change in the volume of the prostate measured on T2W MRI. Therefore, WP volumes calculated on ERC MRI can be reliably used in clinical workflow.

Publisher

Hindawi Limited

Subject

Radiology Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3