Experimental Study on Delivery Performance of an Automated Preloaded Intraocular Lens Injector System for Corneal and Sclerocorneal Incisions

Author:

Oshika Tetsuro1ORCID,Sasaki Noriyuki2

Affiliation:

1. Department of Ophthalmology, Faculty of Medicine, University of Tsukuba, Ibaraki, Japan

2. Alcon Japan Ltd., Tokyo, Japan

Abstract

Purpose. To evaluate delivery performance of an automated preloaded intraocular lens (IOL) injector systems (AutonoMe) in the porcine eyes. Methods. In the freshly excised porcine eyes, lens removal and IOL implantation were performed. There were 4 groups (10 eyes per group) with different incision site and size: 2.2-mm and 2.4-mm corneal incisions and 2.2-mm and 2.4-mm sclerocorneal incisions. Delivery performance and wound enlargement of AutonoMe were analyzed and compared with those of iTec and iSert from a previous study. Results. There were a few minor troubles associated with AutonoMe, such as overriding plunger within cartridge and trapped trailing haptic during IOL insertion, but the incidence was low. Other interactions were not observed, such as IOL adherence to plunger, sudden ejection of IOL, intrawound lens manipulation, IOL behavior, and gross damage to IOL. AutonoMe caused significantly less wound enlargement for both corneal and sclerocorneal incisions than other injector devices. Wound enlargement by using AutonoMe was significantly smaller with 2.4-mm corneal incision than with 2.2-mm corneal incision, but the final incision size was still smaller with 2.2-mm corneal incision. For sclerocorneal incisions, the amount of wound stretch was not different between 2.2 and 2.4 mm incisions. Conclusion. The wound enlargement caused by the automated preloaded insertion system, AutonoMe, was smaller than that of other preloaded injectors for both corneal and sclerocorneal incisions. There were a few minor technical events during IOL insertion, but the overall incidence was low.

Funder

Alcon Research, Ltd.

Publisher

Hindawi Limited

Subject

Ophthalmology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3