Contrast-Enhanced Computed Tomography Does Not Provide More Information about Sarcopenia than Unenhanced Computed Tomography in Patients with Pancreatic Cancer

Author:

Zhang Yan1ORCID,Liu Jiabin2,Li Fei1,Cao Feng1,Li Ang1

Affiliation:

1. Department of General Surgery, Xuanwu Hospital, Capital Medical University, Beijing, China

2. Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing, China

Abstract

Objective. The aim of this study was to understand whether enhanced CT can provide more information than unenhanced CT on diagnosis of sarcopenia. Materials and Methods. We reviewed the enhanced CT data of 45 patients of pancreatic cancer. Manual tracing of the psoas muscles was used for measuring the cross-sectional muscle areas and attenuation at umbilicus level; afterwards, PMI, PMD, and Δ PMD were calculated. Results. In the unenhanced scanning, arterial, venous, and parenchymal phases of enhanced CT, PMI values were 6.905 ± 2.170, 6.886 ± 2.195, 6.923 ± 2.239, and 6.866 ± 2.218, respectively, and the difference was not statistically significant. The PMD values at different phases were 34.311 ± 7.535, 37.487 ± 7.118, 40.689 ± 7.116, and 42.989 ± 7.745, respectively, which were gradually increased, and the difference was statistically significant. Meanwhile, the PMD of arterial phase, venous phase, and parenchyma phase showed a linear correlation with PMD of unenhanced scanning phase. 31 patients had low PMD and 14 had normal PMD during the unenhanced scanning phase. With the addition of contrast agent, ΔPMD values increased faster in the low PMD group than in the normal PMD group during the venous and parenchymal phases (7.048 ± 3.067 vs 4.893 ± 2.558; 9.581 ± 3.033 vs 6.679 ± 2.621; p < 0.05 ), which made the gap between PMD after contrast-enhancement vs. unenhanced scanning smaller. Conclusion. The use of contrast agent has no effect on the manually measured PMI values but can change the results of PMD. This change makes the difference of PMD in different enhancement phases smaller than that in plain scan phase and furthermore increases the examination cost; therefore, it is not recommended to use enhanced CT routinely with fixed dose administration of contrast agent for patients’ assessment of PMI and PMD.

Publisher

Hindawi Limited

Subject

Radiology Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3