Visual Performance after a Unilateral or Bilateral Implantation of Enlarged Depth-of-Focus Intraocular Lens in Patients with Cataract: A Prospective Clinical Trial

Author:

Choi Se Hyun12ORCID,Lee Hyo kyung12ORCID,Yoon Chang Ho12ORCID,Kim Mee Kum12ORCID

Affiliation:

1. Department of Ophthalmology, Seoul National University College of Medicine, Seoul, Republic of Korea

2. Laboratory of Ocular Regenerative Medicine and Immunology, Seoul Artificial Eye Center, Seoul National University Hospital Biomedical Research Institute, Seoul, Republic of Korea

Abstract

Purpose. To investigate visual performances after a unilateral or bilateral implantation of enlarged depth-of-focus intraocular lens in patients with cataract. Methods. In this prospective study, uneventful phacoemulsification and TECNIS® Symfony intraocular lens implantation were performed in 20 eyes of 17 patients. At postoperative 1, 4, and 12 weeks, the logarithm of the minimal angle of resolution visual acuity at far, intermediate, and near distances and the spherical equivalent in manifest refraction and automated refraction were measured. A questionnaire was used to investigate glare, spectacle dependency, and satisfaction at 12 weeks. The mean numerical error and mean absolute error were compared between intraocular lens formulas to assess the best-fit formula. Results. The logarithm of the minimal angle of resolution visual acuity significantly improved to 0.02 at far, 0.02 at intermediate, and 0.27 at near distances at 12 weeks (p<0.05). Spherical equivalent was −0.79 D on automated refraction and was significantly lower than −0.26 D measured on manifest refraction. Patients’ satisfaction score was 9.06, 8.94, and 6.65 for far, intermediate, and near distances, respectively. Near glasses were required in 5 patients and 2 patients complained of photic phenomenon. Visual performances were not significantly different between bilateral and unilateral implanted patients. No patients reported bilateral imbalance due to unilateral surgery. The mean numerical error was closest to 0 D using the Barrett Universal II formula. The mean absolute error was not significantly different between these formulas. Conclusion. Unilateral or bilateral implantation of the enlarged depth-of-focus intraocular lens seems to be equally effective in improving visual performances in patients with cataract.

Publisher

Hindawi Limited

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3