Abstract
Aim. Analysis of the functional results of new IOL with an extended depth of focus implantation a in the short-term (6 months) follow-up period.Patients and methods. The prospective study included 27 patients (40 eyes) after bilateral (n = 12) or monolateral (n = 15) implantation of EDOF IOL Tecnis Symfony with an average follow-up period of 6.5 ± 0.2 (6–7) months. In all cases, IOL implantation was preceded by cataract phacoemulsification or removal of the transparent lens for refractive purposes. The age range was from 39 to 78 (60.6 ± 10.1) years. EDOF IOL Tecnis Symfony ZXR00 was implanted in 30 eyes, and toric EDOF IOL Tecnis Symfony ZXT100, ZXT150, ZTX225, and ZXT300 were implanted in 10 eyes in the presence of clinically significant astigmatism.Results. An increase in UCNVA from 0.18 ± 0.04 to 0.79 ± 0.11, UCIVA from 0.21 ± 0.07 to 0.89 ± 0.10, UCDVA from 0.24 ± 0.06 to 0.95 ± 0.16, BCNVA from 0.61 ± 0.05 to 0.80 ± 0.03, BCIVA from 0.58 ± 0.10 to 0.97 ± 0.19, and BCDVA from 0.65 ± 0.08 to 1.0 ± 0.06 (p < 0.05 in all cases). The spherical equivalent of refraction decreased from –4.5 ± 1.8 in the preoperative period to –0.18 ± 0.92 in the follow-up period of 6 months after implantation of the Tecnis Symfony ZXR00 IOL. In the group with toric IOLs, a decrease in the cylindrical component of refraction was shown from 1.33 ± 1.02 (modulo) to 0.61 ± 0.44 (modulo) during the maximum observation period. In all cases, the rotational stability of the implanted IOLs was noted. In 9 patients out of 24 (37.5 %), permanent or periodic optical phenomena were detected, of which 4 patients (16.7 %) had halos, 3 (12.5 %) had glare, and 2 (8.3 %) had difficulty driving in the dark. These side effects did not affect the overall patient satisfaction — 22 patients (91.7 %) rated the result of the operation as “excellent”, and 2 patients (8.3 %) — as “good”.Conclusion. The paper presents an analysis of the first experience in the Russian Federation of implantation of new IOLs with extended depth of focus and their toric version in 27 patients. Data on the effectiveness of this IOL for vision correction at all distances, low frequency of side optical phenomena, and high patient satisfaction are presented. Further comparative studies with other multifocal IOLs are needed.
Publisher
PE Polunina Elizareta Gennadievna
Reference25 articles.
1. Pershin K.B., Pashinova N.F., Tsygankov A.Yu. Presbyopia-correcting surgical options. Cataract and refractive surgery = Kataraktal’naya i refraktsionnaya khirurgiya. 2016;16(2):4–14 (In Russ.).
2. Hutz W.W., Eckhardt H.B., Rohrig B., Grolmus R. Intermediate vision and reading speed with array, Tecnis, and ReSTOR intraocular lenses. J Refract Surg. 2008;24:251–256. DOI: 10.3928/1081597X-20080301-06
3. Pershin K.B., Pashinova N.F., Tsygankov A.Yu., Miyovitch O.P. The outcomes of the implantation of bifocal and trifocal IOLs for presbyopia. Cataract and refractive surgery = Kataraktal’naya i refraktsionnaya khirurgiya. 2016;16(2):23–29 (In Russ.).
4. Wilkins M.R., Allan B.D., Rubin G.S., Findl O., Hollick E.J., Bunce C., Xing W. Moorfields IOL Study Group. Randomized trial of multifocal intraocular lenses versus monovision after bilateral cataract surgery. Ophthalmology. 2013;120:2449–2455.e1. DOI: 10.1016/j.ophtha.2013.07.048
5. Aurich H., Pham D.T. Individualised correction of presbyopia by the use of phacoemulsification: monovision and multifocal lenses. Klin Mon fur Augenheilkd. 2014;231:1004–1007. DOI: 10.1055/s-0034-1383095
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献