Experimental Harmonics Analysis of UPS (Uninterrupted Power Supply) System and Mitigation Using Single-Phase Half-Bridge HAPF (Hybrid Active Power Filter) Based on Novel Fuzzy Logic Current Controller (FLCC) for Reference Current Extraction (RCE)

Author:

Kumar Mahendar1ORCID,Uqaili M.A1,Memon Z.A1,Das Bhagwan2

Affiliation:

1. Department of Electrical Engineering, Mehran University of Engineering and Technology, Jamshoro, Pakistan

2. Department of Electronic Engineering, Quaid-e-Awam University of Engineering, Science and Technology, Nawabshah, Sindh, Pakistan

Abstract

UPS Uninterruptible power supply) is used as backup when the input source, usually the national grid, fails to give power to a load. In addition to the growing use of electronic power devices in industrial and residential systems, such as UPS, controlled rectifiers, SMPS (Switch Mode Power Supplies), and DC Converters, there is a serious problem caused by harmonics in AC mains, which lowers the power quality. Harmonics can cause a variety of problems, including sensitive equipment failure, resonance issues, heated wires, power loss, and inefficient distribution systems. A passive or active power filter could be used to reduce harmonics. However, passive filters are more difficult to design and are bulkier. With the advancement of power electronics, active power filters were developed, and the best combination of both was supplied in the form of hybrid active power filters (HAPF). This study shows an approach to minimizing the harmonics contained in the output of a UPS connected to a nonlinear load. Experiments with several UPS types have been conducted under various nonlinear loads, as well as charging and discharging of batteries, and the proposed technique significantly reduces harmonics in a system with a HAPFs (hybrid active power filter) based on a unique FLCC (fuzzy logic current controller). In this paper, we use a fuzzy logic controller to generate pulse width modulation (PWM) switching signals in a single-phase half-bridge HAPF. The operation of the proposed PWM-FLCC will be studied in a steady and transient state. Based on a connection between the uninterrupted power supply (UPS) supplying a single-phase power to a nonlinear load, different power filter topologies and a brief review of reference current extraction (RCE) methods used in this study were also included and the most common configurations have been compared with their advantages and disadvantages to ensure the right selection of the power filter for UPS connected with the nonlinear load. The results of the investigation demonstrate that the HAPF with the fuzzy logic current controller has reasonable performance, with a significant reduction in current THD down to 1.09%, as per IEEE-519 standard.

Publisher

Hindawi Limited

Subject

Computational Mathematics,Control and Optimization,Control and Systems Engineering

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3