Affiliation:
1. Jilin University, College of Transportation, Changchun 130025, China
2. Jilin Traffic Planning and Design Institute, Changchun 130025, China
Abstract
Culvert is an important part of roads whose healthy operation is related to the efficiency and safety of road transportation. Therefore, it is very important to evaluate the safety of culvert structure by load test. Four types of prefabricated reinforced concrete box culverts (integral BC, round hinged BC, flat seam BC, and mortise BC) were designed in this paper. By designing a scale model test, the sensor system was used to test the mechanical properties of BC, which included dial indicators, strain gauges, and a pressure sensor. The finite element analysis based on material nonlinearity and contact nonlinearity of round hinged BC and integral BC was carried out. After validating the finite element models, mechanical properties of reinforcement and concrete of BCs were analyzed. The experimental results show that the failure mode of BC was tensile failure of concrete at the bottom of top slab under bending action, and integral BC had the maximum carrying capacity. The contact behaviour of sliding and rotating at hinge joints caused the first principal tensile stress of concrete at the internal surface of the side wall below hinge joints.
Funder
National Natural Science Foundation of China
Subject
Civil and Structural Engineering
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献