Rotational Changes in the Distal Tibial Fragment Relative to the Proximal Tibial Fragment at the Osteotomy Site after Open-Wedge High-Tibial Osteotomy

Author:

Sasaki Takahiro1ORCID,Akamatsu Yasushi1,Kobayashi Hideo1,Mitsuhashi Shota1,Nejima Shuntaro1,Kumagai Ken1,Saito Tomoyuki1,Inaba Yutaka1

Affiliation:

1. Department of Orthopaedic Surgery, Yokohama City University School of Medicine, 3-9 Fukuura, Kanazawa-ku, Yokohama, Japan

Abstract

The present study is aimed at assessing the changes in tibial rotation at the osteotomy site after an open-wedge, high-tibial osteotomy (OWHTO) and analysing the factors that affect rotational changes in the distal tibial fragment relative to the proximal tibial fragment at the same site. This study involved 53 patients (60 knees; 16 males and 37 females) with medial osteoarthritis (OA) who underwent OWHTO and preoperative and 3-month postoperative computed tomography (CT) scans. Rotational angles of the distal tibia were measured using Stryker OrthoMap 3D by comparing preoperative and postoperative CTs. The mean rotational angle yielded an external rotation of2.9°±4.8°. There were 17 knees with internal rotations, 37 knees with external rotations, and one knee with no rotation. The rotational angle significantly correlated with the resultant change in the femorotibial angle (correction angle) and the angle between the ascending and transverse osteotomy lines on the anterior osteotomised surface on which a flange was formed with the distal tibial osteotomised surface (flange angle). The flange angle affected the rotation, but it may have been affected by our surgical technique. The rotational angle did not significantly correlate with the change in the angle of the posterior tibial slope or body mass index. There were significant correlations between the rotational angle and correction angle (r=0.42,p<0.05). Additionally, the rotational angle correlated with the flange angle (r=0.41,p<0.05).

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3