Utility of Quantitative 99mTc-MAA SPECT/CT for 90yttrium-Labelled Microsphere Treatment Planning: Calculating Vascularized Hepatic Volume and Dosimetric Approach

Author:

Garin Etienne123,Rolland Yan4,Lenoir Laurence1,Pracht Marc5,Mesbah Habiba6,Porée Philippe6,Laffont Sophie13,Clement Bruno3,Raoul Jean-Luc235,Boucher Eveline35

Affiliation:

1. Department of Nuclear Medicine, Comprehensive Cancer Center Eugène Marquis, CS 44229, 35042 Rennes, France

2. Faculty of Medicine, European University of Brittany, 35043 Rennes, France

3. INSERM U991 Liver Metabolisms and Cancer, 35033 Rennes, France

4. Department of Medical Imaging, Comprehensive Cancer Center Eugène Marquis, CS 44229, 35042 Rennes, France

5. Department of Medical Oncology, Comprehensive Cancer Center Eugène Marquis, CS 44229, 35042 Rennes, France

6. Department of Medical Informatics, Comprehensive Cancer Center Eugène Marquis, CS 44229, 35042 Rennes, France

Abstract

Objectives. The aim of this study was to assess the effectiveness of SPECT/CT for volume measurements and to report a case illustrating the major impact of SPECT/CT in calculating the vascularized liver volume and dosimetry prior to injecting radiolabelled yttrium-90 microspheres (Therasphere). Materials and Methods. This was a phantom study, involving volume measurements carried out by two operators using SPECT and SPECT/CT images. The percentage of error for each method was calculated, and interobserver reproducibility was evaluated. A treatment using Therasphere was planned in a patient with three hepatic arteries, and the quantitative analysis of SPECT/CT for this patient is provided. Results. SPECT/CT volume measurements proved to be accurate (mean error <6% for volumes ≥16 cm3) and reproductive (interobserver agreement = 0.9). In the case report, 99mTc-MAA SPECT/CT identified a large liver volume, not previously identified with angiography, which was shown to be vascularized after selective MAA injection into an arterial branch, resulting in a large modification in the activity of Therasphere used. Conclusions. MAA SPECT/CT is accurate for vascularized liver volume measurements, providing a valuable contribution to the therapeutic planning of patients with complex hepatic vascularization.

Publisher

Hindawi Limited

Subject

Radiology Nuclear Medicine and imaging