Smeenk FW,Janssen JD,Arends BJ,Harff GA,van den Bosch JA,Schonberger JP,Postmus PE
Abstract
At the present time, plastic syringes are most commonly used for collecting arterial blood. The oxygen tension of the arterial blood (Pa,O2) in these syringes may fall. We studied the effect of the type of syringe, metabolism, and storage time on the arterial oxygen pressures measured and on the pulmonary shunt calculated. In 10 patients, 2-3 h after aortacoronary bypass surgery, a 100% oxygen test was performed. Four arterial blood gas samples were withdrawn from each patient in random order, two in glass syringes and two in plastic syringes. One glass and one plastic syringe were stored at room temperature (RT), and the others were stored in ice-water (IW). Each sample was analysed as soon as possible, and repeated 15, 30, 60 and 120 min after sampling. The Pa,O2 measurement in blood in the glass syringe in IW measured as soon as possible after sampling was considered the "gold standard". Pulmonary shunt calculations were performed using the results of the various blood gas analyses. Compared with the "gold standard", all of the other methods showed significant deterioration in the Pa,O2 measurement. The effect due to diffusion was 0.05 kPa x min(-1), and that due to metabolism 0.11 kPa x min(-1). The Pa,O2 in the glass syringes stored in IW remained stable with time. The pulmonary shunt was significantly overestimated when the "gold standard" blood gas results were not used (range 0.8-9.9%). Glass (not plastic) syringes should be used in the 100% oxygen test. The syringe should be cooled immediately, even when the sample is analysed as soon as possible.
Publisher
European Respiratory Society (ERS)
Subject
Pulmonary and Respiratory Medicine
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Pitfalls in the diagnosis and management of acid–base disorders in humans: a laboratory medicine perspective;Journal of Clinical Pathology;2024-07-18
2. Australian and New Zealand Society of Respiratory Science position statement for arterial blood gas sampling;Internal Medicine Journal;2024-07
3. Pre-analytical validity of arterial blood gas samples: A prospective experimental study on changes derived from time delay and mechanical stress;2024-05-14
4. Impact of storage temperature and time before analysis on electrolytes (Na+, K+, Ca2+), lactate, glucose, blood gases (pH, pO2, pCO2), tHb, O2Hb, COHb and MetHb results;Clinical Chemistry and Laboratory Medicine (CCLM);2023-04-21
5. Recommendation for the design of stability studies on clinical specimens;Clinical Chemistry and Laboratory Medicine (CCLM);2023-04-06