Scorza A,Conforto S,D'Anna C,Sciuto S.A
Abstract
To check or to prevent failures in ultrasound medical systems, some tests should be scheduled for both clinical suitability and technical functionality evaluation: among them, image quality assurance tests performed by technicians through ultrasound phantoms are widespread today and their results depend on issues related to scanner settings as well as phantom features and operator experience. In the present study variations on some features of the B-mode image were measured when the ultrasound probe is handled by the technician in a routine image quality test: ultrasound phantom images from two array transducers are processed to evaluate measurement dispersion in distance accuracy, high contrast spatial resolution and penetration depth when probe is handled by the operator. All measurements are done by means of an in-house image analysis software that minimizes errors due to operator’s visual acuity and subjective judgment while influences of ultrasound transducer position on quality assurance test results are estimated as expanded uncertainties on parameters above (measurement reproducibility at 95 percent confidence level): depending on the probe model, they ranged from ±0.1 to ±1.9 mm in high contrast spatial resolution, from ±0.1 to ±5.5 percent in distance measurements error and from ±1 to ±10 mm in maximum depth of signal visualization. Although numerical results are limited to the two examined probes, they confirm some predictions based on general working principles of diagnostic ultrasound systems: (a) measurements strongly depend on settings as well on phantoms features, probes and parameters investigated; (b) relative uncertainty due to probe manipulation on spatial resolution can be very high, i.e. from 10 to more than 30 percent; (c) Field of View settings must be taken into account for measurement reproducibility as well as Dynamic Range compression and phantom attenuation.
Publisher
Bentham Science Publishers Ltd.
Subject
Biomedical Engineering,Medicine (miscellaneous),Bioengineering
Reference19 articles.
1. Dudley N, Russell S, Ward B, Hoskins P.
BMUS QA working party, “The BMUS guidelines for regular quality assurance testing of ultrasound scanners
Ultrasound
2014;
22
: 6-7.
2. Kollman C, de Korte C, Dudley NJ, Gritzmann N, Martin K, Evans DH.
EFSUMB Technical Quality Assurance Group--US-TQA/B, “Guideline for technical quality assurance (TQA) of ultrasound devices (B-Mode) – Version 1.0 (July 2012)
Ultraschall Med
2012;
33
: 544-9.
3. Branca FP, Sciuto SA, Scorza A.
Comparative evaluation of ultrasound scanner accuracy in distance measurement
Rev Sci Instrum
2012;
83
(10)
: 105103.
4. Thijssen JM, Weijers G, de Korte CL.
Objective performance testing and quality assurance of medical ultrasound equipment
Ultrasound Med Biol
2007;
33
(3)
: 460-71.
5. IEC 61391-1: 2006, “Ultrasonics - Pulse-echo Scanners Part 1:
Techniques for Calibrating Spatial Measurement Systems and
Measurement of System Point-spread Function Response”
2006.
Cited by
19 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献