Analysis of Missed Diagnosis of Gastric Lipomas by CT

Author:

Xu Long1ORCID,Zhang Xiao Dong1ORCID,Zeng Chen1ORCID,Yang Han Feng2ORCID

Affiliation:

1. Department of Radiology, Hospital of North Sichuan Medical College. 63 Wenhua Road, Nanchong, Sichuan, 637000, China

2. Department of Interventional Radiology, Hospital of North Sichuan Medical College. 63 Wenhua Road, Nanchong, Sichuan, 637000, China

Abstract

Introduction: Although Computed Tomography (CT) is the most convenient technology for the diagnosis of gastric lipoma, it also has a high rate of missed diagnosis of gastric lipoma. Objective: To analyze the causes of missed diagnosis of gastric lipomas by CT. Methods: We retrospectively studied the CT images and CT diagnosis reports of 25 cases of gastric lipoma confirmed by surgery or clinical follow-up at the Affiliated Hospital of North Sichuan Medical College and Nanchong Central Hospital from 2016 to 2020 and analyzed the causes of missed diagnosis of gastric lipomas. Results: Among the 25 cases of gastric lipomas included in this study, 17 cases (68.0%) were correctly diagnosed by CT, and 8 cases (32.0%) were missed, but there was no case of misdiagnosis. Eighteen cases (72.0%) of gastric lipomas were located in the gastric antrum, 2 cases (8.0%) at the junction of the gastric body and antrum, 5 cases (20.0%) at the fundus of the stomach, 23 cases (92.0%) under the gastric mucosa, and 2 cases (8.0%) under the gastric serous membrane. All gastric lipoma cases were manifested as round or oval-shaped low-density shadows with clear boundaries on CT. 22 cases (88.0%) showed homogeneous low-density shadows while 3 cases (12.0%) mainly showed low-density shadows containing medium-density strips. There was no obvious enhancement in the contrast-enhanced CT scan. The gastric lipoma cases missed by CT were all located under the gastric mucosa of the gastric antrum. When reading the CT images on the default upper abdominal window width and window level, all the missed lesions were similar to the gas image. And the straight meridian of the three lesions was less than 2 cm. Conclusion: Fat density shadow in gastric antrum area was mistaken for gastrointestinal gas. Improper CT image window width and window levels and small gastric lipoma volume, along with insufficient knowledge of gastric lipomas imaging by the clinician, might be the main causes of missed diagnosis of gastric lipomas by CT. Familiarity with the CT manifestations of gastric lipomas and rich clinical experience can improve the rate of correct diagnosis of gastric lipomas by CT.

Funder

Nanchong City School Cooperation Project Fund

Publisher

Bentham Science Publishers Ltd.

Subject

Radiology, Nuclear Medicine and imaging

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3