A different fixation of the femoral component in total knee arthroplasty may lead to preservation of femoral bone stock

Author:

Barink M1,Verdonschot N1,de Waal Malefijt M1

Affiliation:

1. University Medical Centre Nijmegen Orthopaedic Research Laboratory Nijmegen, The Netherlands

Abstract

Good femoral bone stock is important for the stability of the femoral component in revision knee arthroplasty. However, the primary total knee replacement (TKR) may cause significant loss of bone stock in the distal anterior femur. Earlier stress-induced bone remodelling simulations have suggested that a completely debonded component may save bone stock in the distal anterior region. However, these simulations did not consider the fixation of a debonded implant and possible secondary effects of micromotions and osteolysis at the interface. The current study tries to combine the preservation of bone stock with adequate component fixation. Different bone remodelling simulations were performed around femoral knee components with different sizes of bonding area and different friction characteristics of the debonded area. The fixation of the femoral component with different bonding characteristics is quantified with calculated implant-bone interface stresses. The results show that a bonded femoral component with a debonded inner side of the anterior flange may significantly reduce bone resorption in the endangered distal anterior femur, without jeopardizing the fixation of the femoral implant. This effect may be obtained in vivo by using a femoral component with a highly polished inner side of the anterior flange.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. The use of computational models in orthopedic biomechanical research;Human Orthopaedic Biomechanics;2022

2. Investigation of the effect of the angle between femoral and prosthesis mechanical axes on bone remodeling of femur in total knee arthroplasty;Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine;2021-05-13

3. Tibial tray cementation is not necessary for knee revision with titanium metaphyseal sleeves: a mid-term prospective study in AORI 2B defects;Knee Surgery, Sports Traumatology, Arthroscopy;2020-07-30

4. Numerical Study of Prosthetic Knee Replacement Using Finite Element Analysis;Journal of Biomimetics, Biomaterials and Biomedical Engineering;2020-02

5. How to reduce osteopenia in total knee arthroplasty?;European Journal of Orthopaedic Surgery & Traumatology;2018-08-16