Affiliation:
1. Institut für Thermodynamik der Luft- und Raumfahrt (ITLR), Universität Stuttgart, Stuttgart, Germany
Abstract
In the present study, the pressure loss and heat transfer of a two-pass internal cooling channel with engine-similar cross-sections were investigated experimentally. This channel consisted of a trapezoidal leading edge pass, a sharp 180° bend, and a nearly rectangular outlet pass. The investigations focused on the influence of tip-to-web distance and rib configuration on pressure loss and heat transfer. The channel was equipped with skewed ribs (α=45°, P/ e=10, e/ dh=0.1) in an inline and a staggered configuration. The dimensionless tip-to-web distance Wel/ dS was varied from 0.6 to 1.2. The investigated Reynolds number ranged from 15 000 up to 100 000. The experimental results showed a strong increase in pressure loss with decreasing tip-to-web distance, while heat transfer was only slightly increasing. Both rib configurations showed nearly the same heat transfer enhancement in the bend region.
Subject
Mechanical Engineering,Energy Engineering and Power Technology
Cited by
13 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献