The effect of angle on wall shear stresses in a LIMA to LAD anastomosis: Numerical modelling of pulsatile flow

Author:

Freshwater I J1,Morsi Y S1,Lai T1

Affiliation:

1. Faculty of Engineering, Swinburne University of Technology, Melbourne, Victoria, Australia

Abstract

The purpose of this study was to examine the effect of anastomotic angle on the flow patterns and wall shear distributions at the distal anastomosis of a left interior mammary artery (LIMA) graft to the left anterior descending artery (LDA). It is now well recognized that abnormal wall shear stress distributions along the anastomotic bed, around the toe, and around the heel can contribute to the focal development of intimal hyperplasia. However, the exact nature of the interaction between the dominant pulsing flow and the anastomotic angle on wall shear stresses has not been fully investigated numerically. In this study a commercial CFD package was used for three-dimensional flow analysis where the pulsatile waveforms and flowrates used as the boundary conditions are representative of an anastomosed left internal mammary artery and a stenosed left anterior descending coronary artery (intermediate, <70 per cent diameter narrowing). The flow patterns and distributions of time-averaged wall shear stress (TAWSS) and the oscillatory shear index (OSI) for three anastomotic angles of 20, 40, and 60° were evaluated and compared with other published data. The findings indicated that transient, highly disturbed flow patterns occurred in localized regions of the proximal and distal native segments and in the anastomotic domain including recirculation zones, moving points of stagnation, and oscillating wall shear stresses mainly on the bed, at the toe, and at the heel. Moreover, higher anastomotic angles resulted in more extreme variations in TAWSS and OSI values, particularly around the toe and along the bed. In addition, the effect of anastomotic angle on OSI values at the heel followed the same pattern whereas the TAWSS values along the graft at the heel showed a significant increase at the lowest anastomotic angle of 20°.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 40 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3