Muscle Architecture and Subcutaneous Fat Measurements of Rectus Femoris and Vastus Lateralis at Optimal Length Aided by a Novel Ultrasound Transducer Attachment

Author:

Bulbrook Brittany D.1,Chopp-Hurley Jaclyn N.23,Wiebenga Emily G.4,Pritchard Janet M.15,Gatti Anthony A.2,Keir Peter J.1,Maly Monica R.125

Affiliation:

1. Department of Kinesiology, McMaster University, Hamilton, Ontario, Canada

2. School of Rehabilitation Science, McMaster University, Hamilton, Ontario, Canada

3. School of Kinesiology and Health Science, York University, Toronto, Ontario, Canada

4. Department of Kinesiology, University of Waterloo, Waterloo, Ontario, Canada

5. School of Interdisciplinary Science, McMaster University, Hamilton, Ontario, Canada.

Abstract

Purpose: This cross-sectional study determines the sensitivity of muscle architecture and fat measurements of the rectus femoris (RF) and vastus lateralis (VL) muscles from ultrasound images acquired with varying transducer tilt, using a novel transducer attachment, in healthy adults. Secondary objectives were to estimate intrarater and interrater reliability of image measurement and acquisition, respectively. Methods: Thirty healthy adults participated (15 women and 15 men; 25 [SD 2.5] y). Ultrasound image acquisition was conducted by two raters at different transducer tilts relative to the skin: estimated perpendicular, and five measured angles (80°, 85°, 90°, 95°, 100°) using the transducer attachment. Muscle thickness (MT), subcutaneous fat thickness (FT), pennation angle (PA), and fascicle length (FL) were measured. Sensitivity and reliability were assessed using intra-class correlation coefficients (ICCs) and standard error of measurements (SEMs). Results: MT and FT for RF and VL were not sensitive to transducer tilt. However, PA and FL were sensitive to transducer tilt. MT and FT for both muscles showed high ICCs and low SEMs for intrarater and interrater reliability. For PA of both muscles, standardizing transducer tilt improved interrater ICCs and lowered SEMs. Conclusion: MT and FT measurements of RF and VL acquired at 60° knee flexion are robust to varying transducer tilt angles. PA measurements benefit from standardizing transducer tilt.

Publisher

University of Toronto Press Inc. (UTPress)

Subject

Physical Therapy, Sports Therapy and Rehabilitation

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3