Author:
Mozumder A. K.,Akon A. F.,Chowdhury M. S. H.,Banik S. C.
Abstract
An attempt is made to design, fabricate and test a miniature heat pipe with 5 mm diameter and 150 mm length with a thermal capacity of 10 W. Experiments were conducted with and without working fluid for different thermal loads to assess the performance of heat pipe. The working fluids chosen for the study were same as those commonly used namely, water, methanol and acetone. The temperature distribution across the heat pipe was measured and recorded using thermocouples. The performance of the heat pipe was quantified in terms of thermal resistance and overall heat transfer coefficient. The amount of liquid filled was varied and the variation of the performance parameters for varying liquid inventory is observed. Finally, optimum liquid fill ratio is identified in terms of lower temperature difference and thermal resistance and higher heat transfer coefficient. The data reported in this study will serve as a good database for the researchers in this field. Overall heat transfer coefficient of the Miniature heat pipe is found to be the maximum for the Acetone as working fluid.DOI: http://dx.doi.org/10.3329/jme.v41i2.7473
Publisher
Bangladesh Journals Online (JOL)
Cited by
42 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献