Author:
CHANG Hao,HONG Shiming,YU Dehui,PENG Guangjie,YE Daoxing,LIU Jianrui,YUAN Shouqi
Abstract
Self-priming pump as the core equipment for flood fighting and emergency rescue plays an important role in flood prevention and other fields. More importantly, the geometric parameters of the self-priming nozzle directly determine the performance of the self-priming pump. In the previous analysis,only small amount of experiment was conducted to optimize the geometry parameters of self-priming nozzle, and the interaction between the parameters was not considered. In this paper, the full factor test method is employed to explore the main and interaction effect of the nozzle geometric parameters on the self-priming performance, and the order of response to self-priming time is obtained. Meanwhile, a novel self-priming performance model was established, the self-priming time of different geometric parameters self-priming nozzles can be effectively predicted, and the test analysis cycle and production costs were greatly reduced. Finally, the self-priming test under different self-priming height with optimal self-priming nozzle was conducted, the variation regulation between self-priming time and self-priming height was obtained. Therefore, this research could effectively provide the design reference of self-priming nozzles optimization.
Publisher
Kaunas University of Technology (KTU)
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献