Equating NHANES Monitor-Based Physical Activity to Self-Reported Methods to Enhance Ongoing Surveillance Efforts

Author:

WELK GREGORY J.1,LAMOUREUX NICHOLAS R.2,ZENG CHENGPENG3,ZHU ZHENGYUAN3,BERG EMILY3,WOLFF-HUGHES DANA L.4,TROIANO RICHARD P.4

Affiliation:

1. Department of Kinesiology, Iowa State University of Science and Technology, Ames, IA

2. Kinesiology and Sports Science Department, University of Nebraska Kearney, Kearney, NE

3. Department of Statistics, Iowa State University of Science and Technology, Ames, IA

4. National Cancer Institute, National Institutes of Health, Bethesda, MD

Abstract

ABSTRACT Purpose Harmonization of assessment methods represents an ongoing challenge in physical activity research. Previous research has demonstrated the utility of calibration approaches to enhance agreement between measures of physical activity. The present study utilizes a calibration methodology to add behavioral context from the Global Physical Activity Questionnaire (GPAQ), an established report-based measure, to enhance interpretations of monitor-based data scored using the novel Monitor Independent Movement Summary (MIMS) methodology. Methods Matching data from the GPAQ and MIMS were obtained from adults (20–80 yr of age) assessed in the 2011–2014 National Health and Nutrition Examination Survey. After developing percentile curves for self-reported activity, a zero-inflated quantile regression model was developed to link MIMS to estimates of moderate to vigorous physical activity (MVPA) from the GPAQ. Results Cross-validation of the model showed that it closely approximated the probability of reporting MVPA across age and activity-level segments, supporting the accuracy of the zero-inflated model component. Validation of the quantile regression component directly corresponded to the 25%, 50%, and 75% values for both men and women, further supporting the model fit. Conclusions This study offers a method of improving activity surveillance by translating accelerometer signals into interpretable behavioral measures using nationally representative data. The model provides accurate estimates of minutes of MVPA at a population level but, because of the bias and error inherent in report-based measures of physical activity, is not suitable for converting or interpreting individual-level data. This study provides an important preliminary step in utilizing information from both device- and report-based methods to triangulate activity related outcomes; however additional measurement error modeling is needed to improve precision.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3