Impact of omitting the intravenous heparin bolus on outcomes of leadless pacemaker implantation

Author:

Huang Jingwen1,Bhatia Neal K.1,Lloyd Michael S.1ORCID,Westerman Stacy1,Shah Anand1,Delurgio David1ORCID,Patel Anshul M.1,Tompkins Christine1,El‐Chami Mikhael F.1ORCID,Merchant Faisal M.1

Affiliation:

1. Department of Medicine, Division of Cardiology Emory University School of Medicine Atlanta Georgia USA

Abstract

AbstractBackgroundEarly guidance recommended a bolus of intravenous heparin at the beginning of leadless pacemaker (LP) implantation procedures. However, due to concern about bleeding complications, more recent practice has tended toward omitting the bolus and only running a continuous heparin infusion through the introducer sheath. The impact of omitting the heparin bolus on procedural outcomes is not clear.MethodsWe reviewed all Medtronic Micra LP implants at our institution from 9/2014 to 9/2022. The decision to bolus with heparin was at operator discretion.ResultsAmong 621 LP implants, 326 received an intravenous heparin bolus, 243 did not, and 52 patients were excluded because heparin bolus status could not be confirmed. There was a trend toward more frequent omission of the heparin bolus with more recent implants. Median follow‐up after LP implant was 14.3 (interquartile range [IQR]: 8.4–27.9) months. There was no difference between heparin bolus and no bolus groups in the number of device deployments/recaptures (1.42 ± 0.81 vs. 1.31 ± 0.66, p = .15). Implant‐related adverse events were also similar between heparin bolus and no bolus groups: access‐site hematoma requiring intervention (7 vs. 5, p = .99), pseudoaneurysm (1 vs. 1, p = .99), cardiac perforation (1 vs. 1, p = .99), intraprocedural device thrombus formation (2 vs. 4, p = .41), 30‐day rehospitalization (21 vs. 15, p = .98), and 30‐day all‐cause mortality (16 vs. 14, p = .70). There was one additional nonfatal cardiac perforation in a patient who was excluded due to unknown heparin bolus status. Regarding device electrical parameters between heparin bolus and no bolus groups, there were no significant differences at the time of implant: pacing capture threshold 0.5 ± 0.4 vs. 0.5 ± 0.3, p = .10; pacing impedance 739.9 ± 226.4 vs. 719.1 ± 215.4, p = .52; R wave sensing 11.7 ± 5.7 vs. 12.0 ± 5.4, p = .34). Long‐term device performance was also similar between groups.ConclusionOmission of the systemic heparin bolus at the time of LP implantation appears safe in appropriately selected patients. Heparin bolus may still be considered in long cases requiring multiple device deployments or in patients at high risk for thrombotic complications.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3