Leadless versus transvenous single‐chamber ventricular pacemakers: 3 year follow‐up of the Micra CED study

Author:

Crossley George H.1ORCID,Piccini Jonathan P.2ORCID,Longacre Colleen3,Higuera Lucas3,Stromberg Kurt3,El‐Chami Mikhael F.4ORCID

Affiliation:

1. Vanderbilt University Medical Center Nashville Tennessee USA

2. Duke University Medical Center & Duke Clinical Research Institute Durham North Carolina USA

3. Medtronic, Inc. Minneapolis Minnesota USA

4. Emory University School of Medicine Atlanta Georgia USA

Abstract

AbstractIntroductionThe Micra Coverage with Evidence Development (CED) Study is a novel comparative analysis of Micra (leadless VVI) and transvenous single‐chamber ventricular pacemakers (transvenous VVI) using administrative claims data. To compare chronic complications, device reinterventions, heart failure hospitalizations, and all‐cause mortality after 3 years of follow‐up.MethodsUS Medicare claims data linked to manufacturer device registration information were used to identify Medicare beneficiaries with a de novo implant of either a Micra VR leadless VVI or transvenous VVI pacemaker from March 9, 2017 to December 31, 2018. Unadjusted and propensity score overlap‐weight adjusted Fine‐Gray competing risk models were used to compare outcomes at 3 years.ResultsLeadless VVI patients (N = 6219) had a 32% lower rate of chronic complications and a 41% lower rate of reintervention compared with transvenous VVI patients (N = 10 212) (chronic complication hazard ratio [HR] 0.68; 95% confidence interval [CI], 0.59−0.78; reintervention HR 0.59; 95% CI 0.44−0.78). Infections rates were significantly lower among patients with a leadless VVI (<0.2% vs. 0.7%, p < .0001). Patients with a leadless VVI also had slightly lower rates of heart failure hospitalization (HR 0.90; 95% CI 0.84−0.97). There was no difference in the adjusted 3‐year all‐cause mortality rate (HR 0.97; 95% CI, 0.92−1.03).ConclusionThis nationwide comparative evaluation of leadless VVI versus transvenous VVI de novo pacemaker implants demonstrated that the leadless group had significantly fewer complications, reinterventions, heart failure hospitalizations, and infections than the transvenous group at 3 years, confirming that the previously reported shorter‐term advantages associated with leadless pacing persist and continue to accrue in the medium‐to‐long‐term.

Publisher

Wiley

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3