Half‐volume validation of the NGM Detect™ PCR Amplification Kit and its application on degraded casework samples

Author:

Magonyi Nóra M.1ORCID,Megadja Bálint2,Rádóczy Katalin A.1ORCID,Cseppentő Tamás1ORCID,Lőrincz Eszter É.1ORCID,Valis Norbert G.1,Mátrai Norbert1ORCID,Heinrich Attila1ORCID

Affiliation:

1. Department of Genetics Hungarian Institute for Forensic Sciences Budapest Hungary

2. Department of Surgery Szent Margit Hospital Budapest Hungary

Abstract

AbstractThe NGM Detect™ PCR Amplification Kit was designed particularly for genotyping degraded casework samples. This study aimed to validate the half‐volume amplification of the kit and to present its successful long‐term application. The validation was performed in accordance to the corresponding guidelines of the Scientific Working Group on DNA analysis methods and the European Network of Forensic Science Institutes. For validation parameters, such as sensitivity, reproducibility, and repeatability, polymerase chain reactions (PCR) were set up both manually and robotically, applying 29 cycles. For PCRs with sub‐optimal DNA input (≤0.5 ng) the cycle numbers were increased to 31. Regardless of the PCR preparation method, the optimal 0.5 ng DNA input produced optimal allelic peak heights with no allelic dropout. The first alleles that failed to amplify started to appear at the level of 0.0375 ng input DNA, although the manually prepared PCRs produced fewer missing alleles. In this case, the raised cycle number produced 1.9% and 4.4% of dropout for manually and for robotically set up PCRs, respectively. In the case of 84 degraded casework samples, PCRs were prepared only by hand. The kit was able to provide informative profiles for 78.57%, 70.37%, and 69.77% for lowly, moderately, and highly degraded samples, respectively. Allelic dropouts were 26.05%, 44.88%, and 51.23% for the same groups. According to our results, we strongly recommend using the NGM Detect™ Kit in half‐volume PCR system and encourage the usage of the kit in the particular cases when other kits fail to produce a complete DNA profile.

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3