Comparative Analysis of Five Forensic PCR Kits in Duplets

Author:

Cseppentő Tamás1,Valis Norbert G.1,Bárány Gusztáv1,Megadja Bálint2,Heinrich Attila1ORCID,Magonyi Nóra M.1ORCID

Affiliation:

1. Department of Genetics, Hungarian Institute for Forensic Sciences, Mosonyi u. 9, H-1087 Budapest, Hungary

2. Department of Surgery, Szent Margit Hospital Budapest, Bécsi u. 132, H-1032 Budapest, Hungary

Abstract

In forensic DNA laboratories, it is important to conduct internal validations of the commercially available kits of short tandem repeat (STR) loci and to investigate their individual and combined effectiveness. This study aims to report on a comparative investigation of the forensic kits used in our laboratory and their combinations in analysing low-copy-number (LCN) human DNA samples. We used five partly overlapping multiplex kits with different marker configurations from different manufacturers: the NGM SelectTM PCR Amplification Kit, NGM DetectTM, the GlobalFilerTM Amplification Kit (Applied BiosystemTM, Foster City, CA, USA), the PowerPlex® Fusion 6C System (Promega Co., Madison, WI, USA) and the Investigator® 24plex QS Kit (Qiagen GmbH, Hilden, Germany). The efficacy of the kits was scrutinised by specific criteria, such as allelic dropout rate, the individually calculated Likelihood Ratio (LR) of consensus profiles and the LR value of the composite profile produced by the combined profiles of two kits. According to the results, the pairing of PowerPlex® Fusion 6C System and Investigator® 24plex QS produced the lowest, while the pairing of the NGM DetectTM and GlobalFilerTM kits provided the highest LR value. In summary, our study is meant to aid the selection of the optimal kit combination for samples of different qualities.

Publisher

MDPI AG

Reference19 articles.

1. The Development of Reduced Size STR Amplicons as Tools for Analysis of Degraded DNA;Butler;J. Forensic Sci.,2003

2. Evaluation of The Investigator 26plex Qs and Sureid Panglobal Systems in Forensic Analysis and Comparison with Commonly Used NGM PCR Amplification Kit;Probl. Forensic Sci.,2022

3. Comparison of Different Interpretation Strategies for Low Template DNA Mixtures;Pfeifer;Forensic Sci. Int. Genet.,2012

4. Dual Amplification Strategy for Improved Efficiency of Forensic DNA Analysis Using NGM DetectTM NGMTM or GlobalfilerTM Kits;Kupiec;Forensic Sci. Int. Genet.,2018

5. The Evolution of DNA Databases—Recommendations for New European STR Loci;Gill;Forensic Sci. Int.,2006

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3