An evaluation of mechanical and biophysical skin parameters at different body locations

Author:

John Anto J. U. K.1ORCID,Galdo Francesco Del2ORCID,Gush Rodney3ORCID,Worsley Peter R.1ORCID

Affiliation:

1. School of Health Sciences University of Southampton Southampton UK

2. Raynaud's and Scleroderma Programme, NIHR Biomedical Research Centre Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds Leeds UK

3. Moor Instruments Axminster UK

Abstract

AbstractBackgroundSkin is the largest organ in the body, representing an important interface to monitor health and disease. However, there is significant variation in skin properties for different ages, genders and body regions due to the differences in the structure and morphology of the skin tissues. This study aimed to evaluate the use of non‐invasive tools to discriminate a range of mechanical and functional skin parameters from different skin sites.Materials and methodsA cohort of 15 healthy volunteers was recruited following appropriate informed consent. Four well‐established CE‐marked non‐invasive techniques were used to measure four anatomical regions: palm, forearm, sole and lower lumbar L3, using a repeated measures design. Skin parameters included trans‐epidermal water loss (TEWL), pH (acidity), erythema, stratum corneum hydration and stiffness and elasticity using Myoton Pro (skin and muscle probe). Differences between body locations for each parameter and the intra‐rater reliability between days were evaluated by the same operator.ResultsThe results indicate that parameters differed significantly between skin sites. For the Myoton skin probe, the sole recorded the highest stiffness value of 1006 N/m (SD ± 179), while the lower lumbar recorded the least value of 484 N/m (SD ± 160). The muscle indenter Myoton probe revealed the palm's highest value of 754 N/m (± 108), and the lower lumbar recorded the least value of 208 N/m (SD ± 44). TEWL values were lowest on the forearm, averaging 11 g/m2/h, and highest on the palm, averaging 41 g/m2/h. Similar skin hydration levels were recorded in three of the four sites, with the main difference being observed in the sole averaging 13 arbitrary units. Erythema values were characterised by a high degree of inter‐subject variation, and no significant differences between sites or sides were observed. The Myoton Pro Skin showed excellent reliability (intra‐class correlation coefficients > 0.70) for all sites with exception of one site right lower back; the Myoton pro muscle probes showed good to poor reliability (0.90–017), the corneometer showed excellent reliability (>0.75) among all the sites tested, and the TEWL showed Good to poor reliability (0.74–0.4) among sites.ConclusionThe study revealed that using non‐invasive methods, the biophysical properties of skin can be mapped, and significant differences in the mechanical and functional properties of skin were observed. These parameters were reliably recorded between days, providing a basis for their use in assessing and monitoring changes in the skin during health and disease.

Publisher

Wiley

Subject

Dermatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3