Author:
Chrzanowski Krzysztof,Nguyen Hong Viet
Abstract
Minimum resolvable temperature difference (MRTD) is considered as the most important parameter of thermal imagers. A new method of MRTD measurement without drawbacks of other methods is presented in this paper. Proposed MRTD measurement method coded as virtual MRTD is based on a three steps measurement concept using semi-automatic objective measurements and computer simulation. First, objective parameters of the tested thermal imager are measured. Second, software simulates this tested thermal imager and generates the image of 4-bar target of specified spatial frequency (size) and contrast (temperature difference). Third, a human observer analyses the images of the 4-bar target generated by the software on the screen of PC set and measures MRTD of the simulated thermal imager at specified set of spatial frequencies. The proposed method offers higher measurement speed, lower cost and typically better accuracy in comparison with the typical MRTD measurement method.
Publisher
Politechnika Wroclawska Oficyna Wydawnicza
Subject
Atomic and Molecular Physics, and Optics,Electronic, Optical and Magnetic Materials
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献