Author:
Blatz James A,Ferreira Nelson J,Graham James
Abstract
In 1999, after a period of extensive rainfall, two shallow slope failures developed in the right-of-way of Provincial Road 259 near Virden, Manitoba. The rainfall caused dissipation of soil suction in the near-surface soil, thereby reducing shear resistance and triggering failure. A research project was initiated between the Geotechnical Group at the University of Manitoba and the Manitoba Department of Highways and Transportation to assess the mechanism of failure. The project included a field investigation program, laboratory testing program, and advanced numerical modeling to identify the cause of failure. The results demonstrate that the rainfall resulted in dissipation of the suction in the soil slope, resulting in a reduction in the soil shear strength that triggered shallow failures. The dissipation of the soil suction has been modeled using a time-dependent seepage model that accounts for the flux boundary condition that existed at the ground surface.Key words: slope stability, unsaturated soils, laboratory tests, soil suction, seepage modeling, flux boundary.
Publisher
Canadian Science Publishing
Subject
Civil and Structural Engineering,Geotechnical Engineering and Engineering Geology
Cited by
34 articles.
订阅此论文施引文献