Abstract
A mechanical injection system needing little maintenance is described which offers a dependable and flexible method for maintaining multiple toxicant concentrations in flow-through bioassays. Falling water from a series of water-metering cells similar to those of a proportional diluter, activates a series of mechanical syringe injectors. The system dispenses equal amounts of toxicant dispersants (solvents, wetting agents, or additives) to all toxicant concentrations and to a dispersant control and allows changing unlimited toxicant concentrations independently of each other.