Experiments with Stand-Alone Sand-Screen Specimens for Thermal Projects

Author:

Fattahpour Vahidoddin1,Roostaei Morteza1,Hosseini Seyed Abolhassan2,Soroush Mohammad2,Berner Kelly1,Mahmoudi Mahdi1,Al-hadhrami Ahmed3,Ghalambor Ali4

Affiliation:

1. RGL Reservoir Management Inc.

2. University of Alberta

3. Occidental Petroleum Oman

4. Oil Center Research International

Abstract

Summary Most of the test protocols developed to evaluate sand-screen designs were based on scaled-screen test coupons. There have been discussions regarding the reliability of such tests on scaled test coupons. This paper presents the results of tests on wire-wrapped screen (WWS) and slotted liner (SL) test coupons for typical onshore Canada McMurray formation sand. A unique sand control evaluation apparatus has been designed and built to accommodate all common stand-alone screens that are 3.5 in. in diameter and 12 in. in height. This setup provides the capability to have a radial measurement of pressure across the sandpack and screen for three-phase flow. Certain challenges during testing such as establishing uniform radial flow and measuring the differential pressure are outlined. Produced sand is also measured during the test. The main outputs of the test are to assess the sand control performance and the mode of sanding in different flow directions, flow rates, and flow regimes. It was possible to establish uniform radial flow in both high- and low-permeability sandpacks. However, the establishment of radial flow in sandpacks with very high permeability was challenging. The pressure measurement at different points in the radial direction around the screen indicated a uniform radial flow. Results of the tests on a representative particle size distribution (PSD) from the McMurray Formation on the WWS and SL test coupons with commonly used specifications in the industry (aperture sizes of 0.012, 0.014, and 0.016 in. for WWS and 0.012, 0.016, 0.018, and 0.020 in. for SL) have shown similar sanding and flow performances. We also included aperture sizes smaller and larger than the common practice. Similar to previous tests, narrower apertures are proven to be less resistant to plugging than wider slots for both WWS and SL. Accumulation of fines close to the screen causes significant pore plugging when conservative aperture sizes were used for both WWS and SL. In contrast, using the test coupon with a larger aperture size than the industry practice resulted in excessive sanding. The experiments under linear flow seem more conservative because their results show more produced sand and smaller retained permeability in comparison to the testing under radial flow. This work discusses the significance, procedure, challenges, and early results of physical modeling of stand-alone screens in thermal operation. It also provides insight into the fluid flow, fines migration, clogging, and bridging in the vicinity of sand screens.

Publisher

Society of Petroleum Engineers (SPE)

Subject

Mechanical Engineering,Energy Engineering and Power Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3