Continuous Methane Monitoring: Equivalency Evaluation of Regulator-Approved Alternative Leak Detection and Repair Program in Alberta, Canada

Author:

Benko Tim1ORCID,MacGregor Alex2ORCID,Wen Eric3ORCID,Fox Thomas4ORCID,Moorhouse Brendan4ORCID

Affiliation:

1. Enhance Energy

2. Qube Technologies

3. Qube Technologies (Corresponding author)

4. Highwood Emissions Management

Abstract

Summary Diverse methods have emerged for methane leak detection and repair (LDAR), alongside a growing interest in continuous monitoring (CM). Novel LDAR programs must demonstrate equivalent (or better) emissions reductions compared to conventional handheld methods to be approved by regulators and trusted by industry. We apply and test a widely accepted equivalency framework and report on a regulatory approved alternative LDAR pilot program to evaluate the performance of CM relative to conventional LDAR. The framework, which has not been formally tested to date, relies on a combination of controlled release testing, simulation modeling, and field piloting. First, controlled release testing at known emission rates is used to establish probability of detection functions and other performance metrics for the CM device. Performance metrics are then used to build a CM module in LDAR Simulator (LDAR-Sim), an open-access modeling framework. Finally, CM devices are deployed as part of a field pilot. Controlled release testing results and dispersion modeling suggest that the CM devices can reliably detect (i.e., 90% detection probability or greater) a rate of 1 kg/h (~54 scf/hr) from distances of 75–100 m with no false positive detections. A set of work practices were established using the LDAR-Sim framework. The CM program requires close-range follow-up for any detection event and is estimated by LDAR-Sim to reduce aggregate annual fugitive methane emissions by 91.8% relative to the baseline, doubling the reductions anticipated from a conventional regulatory program. For the pilot, 52 devices are deployed across 16 facilities with Enhance Energy. All devices are positioned within 100 m of monitored assets. Each time devices record a detection event, which is defined as a sustained anomaly three standard deviations above a moving average background concentration for 24 hours, 7 days, or 60 days, the operator performs a close-range follow-up inspection. Preliminary results show that the CM devices can detect leaks and that follow-up protocols are effective at immediately finding leaks and avoiding false positives. Confirmed detections include fugitive emissions such as a tank thief hatch leak and vented emissions including high-bleed pneumatics. Both types of emissions were confirmed as repaired or improved by CM. These results indicate that repairing leaks more expeditiously through faster detection can reduce emissions by up to 90%.

Publisher

Society of Petroleum Engineers (SPE)

Subject

Energy Engineering and Power Technology,Fuel Technology,General Earth and Planetary Sciences,General Environmental Science

Reference12 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3