Comparison of Different Methods to Evaluate the Effect of Temperature on Polymer Retention and Degradation in the Presence and Absence of Oil on Carbonate Outcrops

Author:

Sebastian Anoo1,Musthaq Muhammad1,Al-Shalabi Emad W.2,AlAmeri Waleed2,Mohanty Kishore3,Masalmeh Shehadeh4,AlSumaiti Ali M.4

Affiliation:

1. Chemical and Petroleum Engineering Department, Khalifa University of Science and Technology, Abu Dhabi, UAE.

2. Chemical and Petroleum Engineering Department, Research and Innovation Center on CO2 and Hydrogen, Khalifa University of Science and Technology, UAE.

3. Hildebrand Department of Petroleum and Geosystems Engineering, The University of Texas at Austin, USA.

4. Abu Dhabi National Oil Company – Upstream, UAE.

Abstract

Abstract Polymer retention poses a significant challenge in polymer flooding applications, emphasizing the importance of accurately determining retention levels for successful project design. In carbonate reservoirs of the Middle East, where temperatures exceed 90 °C, conducting adsorption tests under similar temperature conditions becomes crucial for the precise determination of adsorption values. The choice of analytical method heavily impacts the accuracy of retention measurements from effluent analysis. This study investigates the effect of temperature on the performance of a polymer, specifically its rheological behavior and retention. Rheological and polymer flooding experiments were carried out using an ATBS-based polymer in formation water (167,114 ppm) at different temperatures (25, 60, and 90 °C) with required oxygen control measures. Dynamic polymer retention was conducted in both absence of oil (single-phase tests) and presence of oil (two-phase tests). In addition, different analytical techniques were evaluated, including viscosity measurements, UV-visible spectroscopy, and TOC-TN analysis, to determine the most accurate method for measuring the polymer concentration with the least associated uncertainty. Furthermore, the study investigates the effects of these uncertainties on the final dynamic polymer retention values by applying propagation of error theory. The effluent polymer concentration was determined using viscosity correlation, UV spectrometry, and TOC-TN analysis, all of which were reliable methods with coefficient of determination (R2) values of ∼0.99. The study analyzed the effects of flow through porous media and back-pressure regulator on polymer degradation. The results showed that the degradation rates were around 2% for flow through porous media and 16% for mechanical degradation due to the back-pressure regulator for all temperature conditions. For the effluent sample, the concentration of effluents was lower when using the viscosity method due to polymer degradation. However, the TOC-TN and UV methods were unaffected as they measured the total nitrogen and absorbance at a specific wavelength, respectively. Therefore, all viscosity results were corrected for polymer degradation effects in all tests. During 60 °C single-phase studies, the dynamic retention values obtained from viscosity correlation, UV spectrometry, and TOC-TN analysis were determined to be 52 ± 3, 45 ± 5, and 48 ± 3 μg/g-rock, respectively. During the two-phase coreflooding experiment conducted at 25 °C, the accuracy of the UV spectrometry and viscosity measurements were affected by the presence of oil, rendering these methods unsuitable. However, the TOC-TN measurements were able to deliver a retention of 24± 3 μg/g-rock. Moreover, the use of glycerine preflush to inhibit oil production during polymer injection in the two-phase studies showed that all three methods were appropriate with dynamic retention values of 27± 3, 25±5, and 21±3 μg/g-rock for viscosity, UV, and TOC-TN, respectively at 60 °C. The error range was obtained using the propagation of error theory for all the methods. Accordingly, it was also noted that the temperature did not affect the dynamic retention values in both single-phase and two-phase conditions. The dynamic retention values for single-phase using the UV method and two-phase using the TOC-TN method were 45 – 56 ±5 μg/g-rock and 21 – 26 ±3μg/g-rock, respectively, for the range of temperatures applied. The findings of this study highlight that when adequate oxygen control measures are implemented, the temperature does not exhibit a statistically significant impact on the retention of the ATBS-based polymer under investigation. Furthermore, TOC-TN has been identified as the optimal analytical method due to its minimal uncertainties and ease of measuring polymer concentration under varying experimental conditions.

Publisher

SPE

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3