Affiliation:
1. Bte Bedampfungstechnik GmbH
Abstract
During optical monitoring using broadband transmittance measurement, the accuracy
depends on how both the substrate and the optical path are aligned. We
present a correction procedure to improve the accuracy of the
monitoring, even if the substrate has features such as absorption or
if there is misalignment of the optical path. The substrate in this
case can either be a test glass or a product. The algorithm is proven
by experimental coatings which were produced with and without the
correction. Additionally, the optical monitoring system was also used
to perform an in situ quality check. The system
allows a detailed spectral analysis of all substrates with a high
position resolution. Both plasma and the temperature effects on the
central wavelength of a filter are identified. This knowledge
enables the optimization of the following runs.