Affiliation:
1. Hebei University of Technology
Abstract
To solve the problem of static magnetic field detection accuracy and consistency, we prepared an array of single NV centers for static magnetic field vector and gradient detection using the femtosecond laser direct writing method. The prepared single NV centers are characterized by fewer impurity defects and good stress uniformity, with an average spatial positioning error of only 0.2 µm. This array of single NV centers can achieve high accuracy magnetic field vector and gradient measurement with GBZ≈-0.047 µT/µm in the Z-axis. This result provides a new idea for large-range, high-precision magnetic field vector and gradient measurements.
Funder
National Natural Science Foundation of China
National Key Research and Development Program of China
Strategic Priority Research Program of CAS
Jilin Scientific and Technological Development Program
China Postdoctoral Science Foundation
Subject
Atomic and Molecular Physics, and Optics