Affiliation:
1. Changsha University of Science and Technology
2. Sichuan Gas Turbine Research Institute
Abstract
In this paper, a high-accuracy measurement method for rotor-stator axial clearance in narrow spaces is proposed. The optical path structure based on all-fiber microwave photonic mixing is established. To improve the accuracy and expand the measurement range, the total coupling efficiency over the entire measurement range at different working distances of fiber probe was evaluated by Zemax analysis tool and theoretical model. The performance of the system was verified by experiments. The experimental results show that the measurement accuracy of axial clearance is better than 10.5 um within the range of 0.5–20.5 mm. The measurement accuracy has been effectively improved compared to previous methods. Additionally, the probe size is reduced to a mere diameter of 2.78 mm, which is more suitable for axial clearance measurement in narrow spaces inside rotating machines.
Funder
National Natural Science Foundations of China
National Key Research and Development Plan Project
China Postdoctoral Science Foundation
Joint Fund of Ministry of Education for Equipment Pre-research
National Defense Science and Technology Key Laboratory Fund
Guangdong Province Key Research and Development Plan Project
the Fok Ying Tung Education Foundation
Young Elite Scientists Sponsorship Program by CAST
Subject
Atomic and Molecular Physics, and Optics
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献