Abstract
We report a design and
implementation of proton deflectometry with an in
situ reference x-ray image of a mesh to precisely measure
non-uniform magnetic fields in expanding plasmas at the OMEGA and
OMEGA EP laser facilities. The technique has been developed with
proton and x-ray sources generated from both directly driven capsule
implosions and short pulse laser–solid interactions. The accuracy of
the measurement depends on the contrast of both the proton and x-ray
images. We present numerical and analytic studies to optimize the
image contrast using a variety of mesh materials and grid spacings.
Our results show clear enhancement of the image contrast by factors of
four to six using a high
Z
mesh with large grid spacing. This
leads to further improvement in the accuracy of the magnetic field
measurement using this technique in comparison with its first
demonstration at the OMEGA laser facility [Rev. Sci. Instrum.
93, 023502 (2022)RSINAK0034-674810.1063/5.0064263].