Comparison of Post-Procedural and 30-day Post-Implantation Transcatheter Aortic Valve Replacement Gradients with and without pre-implantation Balloon Valvuloplasty: A Real-World Analysis of Early Results using a Novel Balloon Expandable Transcatheter Aortic Valve

Author:

Chandrasekhar Mahesh1,Zhao David2,Richardson Karl2

Affiliation:

1. Cone Heart and Vascular Institute, 1126 North Church Street, Suite #300, Greensboro, North Carolina USA, 27401

2. Wake Forest Baptist Medical Center, 1 Medical Center Blvd, Winston-Salem, NC 27157, United States

Abstract

Objectives: This study describes a real-world experience of implanting a novel balloon expandable transcatheter aortic valve replacement (TAVR) compared to devices commonly used in clinical practice. As a secondary objective, the effect of balloon angioplasty (BAV) before TAVR on the transvalvular gradient 1 and 30 days after implantation was evaluated. Background: For most commercial TAVR valves, the 30-day average mean aortic valve gradients have been reported. Our experience with the Lotus Valve System had indicated higher immediate post-implant gradients than those in the literature. We sought to evaluate both these valves, comparing them to other valves. Methods: We analyzed discharge and 30-day echocardiograms of Lotus valves from 7/5/2019 to 8/27/2020. In response to higher-than-expected post-implant gradients, patients from 11/4/19 to 8/27/20 underwent BAV before the valve implantation, whereas patients from 7/5/19 to 10/18/19 did not (no-BAV). We compared these samples to each other and to a random sampling of TAVR valves implanted by the same interventionalist. Results: At discharge, 27 patients received Lotus valves. The average mean aortic valve gradient was 16.7 mmHg (SD = 5.5 mmHg) for the no-BAV and 14.7 mmHg (SD = 3.7 mmHg) for the BAV (P = 0.177) cohorts. No-BAV Lotus valve mean gradients were significantly higher (P < 0.001) than those of the Sapien valve (M = 12 mmHg, SD = 4.3) and CoreValve (M = 9.18 mmHg, SD = 3.96). At the 30-day assessment, the mean gradients in the no-BAV and BAV groups were similar to those in the literature (M = 11 mmHg SD 3.5; M = 12 mmHg, SD 4.1 (P = 0.287)) and those of other valves. Conclusions: The Lotus valve demonstrated higher post-implantation gradients than other valves. This effect was not attenuated by BAV. These elevated gradients were not significant at the 30-day follow-up.

Publisher

Compuscript, Ltd.

Subject

General Medicine

Reference8 articles.

1. Two-year outcomes after transcatheter aortic valve replacement with mechanical vs self-expanding valves: the REPRISE III randomized clinical trial;MJ Reardon;JAMA Cardiol,2019

2. Relationship between invasive and echocardiographic transvalvular gradients after transcatheter aortic valve replacement;SH Aalaei-Andabili;Cardiol Ther,2020

3. Invasive versus echocardiographic evaluation of transvalvular gradients immediately post-transcatheter aortic valve replacement demonstration of significant echocardiography-catheterization discordance;AE Abbas;Circ Int,2019

4. Doppler assessment of mechanical aortic valve prostheses: effect of valve design and size of the aorta;J Mascherbauer;J Heart Valve Dis,2004

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3