Radiation dose metrics in multidetector computed tomography examinations: A multicentre retrospective study from seven tertiary care hospitals in Kerala, South India

Author:

Varghese Binoj1,Kandanga Indu2,Puthussery Paul3,Vijayan Dhanesh4,Babu S P Harish5,Aneesh M K6,Noufal Muhammad7,Binu E V8,Babu Arun C1,James Sheen M1,Kumar Siva1

Affiliation:

1. Department of Radiodiagnosis, Amala Institute of Medical Sciences, Kerala, India

2. Department of Radiodiagnosis, Amala Institute of Medical Sciences, Thrissur and University Hospital of North Durham, Durham, United Kingdom

3. Department of Radiodiagnosis, Govt Medical College, Thrissur, Kerala, India

4. Department of Radiodiagnosis, Travancore Medical College Hospital, Kollam, Kerala, India

5. Department of Radiodiagnosis, Baby Memorial Hospital, Kozhikode, Kerala, India

6. Department of Radiodiagnosis, Jubilee Mission Medical College and Research Institute, Thrissur, Kerala, India

7. Star Care Hospital, Kozhikode, Kerala, India

8. Department of Radiodiagnosis, Daya Hospital, Thrissur, Kerala, India

Abstract

Abstract Background: Presently, computed tomography (CT) is the most important source of medical radiation exposure. CT radiation doses vary considerably across institutions depending on the protocol and make of equipment. India does not yet have national or region-specific CT diagnostic reference levels. Aim: To evaluate radiation doses of consecutive multidetector CT (MDCT) examinations based on anatomic region, performed in 1 month, collected simultaneously from seven tertiary care hospitals in Kerala. Settings and Design: Descriptive study. Materials and Methods: We collected the CT radiation dose data of examinations from the seven collaborating tertiary care hospitals in Kerala, performed with MDCT scanners of five different makes. The data included anatomic region, number of phases, CT dose index (CTDIvol), dose-length product (DLP), and effective dose (ED) of each examinations and patient demographic data. Statistical Analysis: We calculated the 25th, 50th, and 75th percentiles of the CTDIvol, DLP, and ED according to anatomic region. We made descriptive comparisons of these results with corresponding data from other countries. Results: Of 3553 patients, head was the most frequently performed examination (60%), followed by abdomen (19%). For single-phase head examinations, 75th percentile of CTDIvolwas 68.1 mGy, DLP 1120 mGy-cm, and ED 2.1 mSv. The 75th percentiles of CTDIvol, DLP, and ED for single-phase abdomen examinations were 10.6, 509.3, and 7.7, and multiphase examinations were 14.6, 2666.9, and 40.8; single-phase chest examinations were 23.4, 916.7, and 13.38, and multiphase examinations were 19.9, 1737.6, and 25.36; single-phase neck were 24.9, 733.6, and 3.814, and multiphase neck were 24.9, 2076, and 10.79, respectively. Conclusion: This summary CT radiation dose data of most frequently performed anatomical regions could provide a starting point for institutional analysis of CT radiation doses, which in turn leads to meaningful optimization of CT.

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3