The diagnostic accuracy of perfusion-only scan in the diagnosis of pulmonary embolism in the era of COVID-19: A single-center study of 434 patients

Author:

Cengiz Turgut Bora1,Abdelrahman Ahmed1,Rohren Scott A.1,Doucette John1,Ghesani Munir1

Affiliation:

1. Department of Diagnostic, Molecular and Interventional Radiology, Division of Nuclear Medicine, Mount Sinai Hospital, New York, NY, USA

Abstract

Abstract: INTRODUCTION: There is a paucity of data in the literature regarding the diagnostic accuracy of perfusion (Q)-only studies in the absence of ventilation images. This study aims to assess the diagnostic accuracy of Q-only imaging in the pandemic era. METHODS: Patients who underwent Q-only imaging for pulmonary embolism between March 2020 and February 2021 were analyzed. Patients who underwent lung quantification analysis were excluded. Q-only test results were reported as per modified PIOPED II criteria and single positron emission tomography/computed tomography (SPECT/CT) imaging was performed as needed. Patients were considered concordant or discordant by correlating the Q-only results with CT angiogram (CTA) or clinical diagnosis made through chart review. The diagnostic accuracy was calculated after excluding intermediate probability and nondiagnostic studies. RESULTS: Four hundred and thirty-four patients were identified. One hundred and twenty-eight patients (29.4%) underwent ultrasound Doppler, 37 patients (8.5%) underwent CTA, and 16 patients (3.6%) underwent both. After excluding patients with intermediate probability or nondiagnostic studies and who did not have follow-up (a total of 87 patients [20%]), 347 patients were enrolled in the final analysis. The combined planar and SPECT/CT sensitivity and specificity were 85.4% (72.2%–93.9% confidence interval [CI]) and 98.7% (96.9%–98.6% CI), respectively. The positive predictive value (PPV) of the Q-only imaging was 89.1% (77.3%–95.1% CI) and the negative predictive value (NPV) was 98.2% (96.4%–99% CI). The sensitivity with SPECT/CT reached 100% (CI: 71.5%–100%) with a specificity of 92.3% (CI: 64%–99.8%). The PPV was 85.7% (CI: 62.1%–95.6%) and the NPV was 100%. CONCLUSION: Q-only imaging provides clinically acceptable results. The sensitivity of the Q-only scan is increased when coupled with SPECT/CT.

Publisher

Medknow

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3