Prospects for Clinical Applications of Polymer-Coated Haemoconcentrator on Extracorporeal Circuit in Cardiopulmonary Bypass Surgeries

Author:

Tagaya Masashi1,Takahashi Shunsuke2,Matsuda Morihiro3,Takasaki Taiichi4,Hamaishi Makoto4,Hara Kazunobu1

Affiliation:

1. Department of Medical Engineering, National Hospital Organization Kure Medical Centre and Chugoku Cancer Centre, Hiroshima - Japan

2. Department of Nephrology, National Hospital Organization Kure Medical Centre and Chugoku Cancer Centre, Hiroshima - Japan

3. Department of Internal Medicine, National Hospital Organization Kure Medical Centre and Chugoku Cancer Centre, Hiroshima - Japan

4. Division of Cardiovascular Surgery, National Hospital Organization Kure Medical Centre and Chugoku Cancer Centre, Hiroshima - Japan

Abstract

Purpose Extracorporeal circulation circuits used in cardiopulmonary bypass surgeries are increasingly being coated with polymer materials to reduce the thrombogenicity of extracorporeal devices. However, a haemoconcentrator, which corrects haematocrit and electrolyte imbalances, is not coated with polymers. In this study, we sought to assess the filtration performance of polymer-coated haemoconcentrators in order to obtain insight into their prospects for use in clinical applications. Methods In vitro experiments were performed to evaluate the water pressure and flow properties of polymer-coated haemoconcentrators by comparing 3 polymer-coated haemoconcentrators with 3 non-coated haemoconcentrators. The cross-sectional surfaces of both types of haemoconcentrators were observed using a scanning electron microscope (SEM). Results The slopes of the regression lines for estimating the filtrated fluid flow as a function of the transmembrane pressure were 6.286 ± 0.320 for polymer-coated haemoconcentrators and 3.712 ± 0.170 for non-coated haemoconcentrators. These slopes were found to be significantly different and indicate that the filtration velocity is enhanced in polymer-coated haemoconcentrators over that in non-coated haemoconcentrators. However, the hollow fibre damage observed by SEM was not shown to contribute to higher filtration flow in the polymer-coated haemoconcentrator. Taking these results into consideration, we hypothesise that a polymer coating makes a foreign surface on a hollow fibre slippery, owing to the hydrophobicity of the polymer, thereby enhancing the velocity of the filtration. Conclusions The results of this preliminary investigation suggest that a polymer coating can enhance the filtration performance of a haemoconcentrator and that polymer-coated haemoconcentrators might be useful in clinical applications.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3