Influence of Different Oxygenator Types on Changing Frequency, Infection Incidence, and Mortality in Ards Patients on Veno-Venous Ecmo

Author:

Robak Oliver1,Lakatos Philipp K.S.1,Bojic Andja1,Hermann Alexander1,Laczika Klaus-Felix1,Chiari Astrid2,Hiesmayr Jörg M.2,Staudinger Thomas1,Locker Gottfried J.1

Affiliation:

1. Department of Internal Medicine I, Intensive Care Unit, Medical University of Vienna, Vienna - Austria

2. Department of Anesthesiology, Medical University of Vienna, Vienna - Austria

Abstract

Purpose Veno-venous extracorporeal membrane oxygenation (vv-ECMO) is pivotal in the treatment of patients suffering from acute respiratory distress syndrome (ARDS). Comparative data with different oxygenator models have not yet been reported. The aim of this retrospective investigation was therefore to assess whether different oxygenator types might influence changing frequency, infection incidence, and mortality in patients on vv-ECMO. Methods 42 patients undergoing vv-ECMO between 1998 and 2009 were identified. In 20 out of these patients, a polypropylene (PP) microporous hollow fiber membrane oxygenator, and in 22 patients a nonmicroporous polymethylpentene (PMP) diffusion membrane oxygenator was used. Infection incidence, changing frequency, and mortality were documented. Results In the PMP group, an oxygenator change was necessary less often than in the PP group (p<0.001). The incidence of bacterial, viral, or fungal growth was similar in the groups, thus independent of the frequency of oxygenator change. Irrespective of the groups, the occurrence of Candida sp. tended to correlate with death (p = 0.06). In general, there was a trend towards a higher infection incidence in the subgroup with pulmonary ARDS (p = 0.07). Moreover, infection incidence was associated with a longer ICU stay (p = 0.03) and longer ECMO therapy (p = 0.03). ICU mortality was lower in the PMP group than in the PP group, although not statistically significant (p = 0.10). Conclusions The PMP oxygenator membranes showed benefits with regards to changing frequency, but not infection incidence, length of ICU stay, and length of ECMO therapy. There was a trend towards a lower ICU mortality in patients with PMP oxygenators.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3