Affiliation:
1. Department of Orthopaedic Surgery, Kanazawa Medical University, Kahokugun, Ishikawa - Japan
Abstract
Introduction There is controversy about which is more suitable for determining correct socket position in patients with severe bone deficiency of the acetabular roof because of developmental dysplasia of the hip (DDH): the anatomic centre of hip rotation or a high centre. Method We evaluated the relationship, in 200 hips, between the centre of rotation and presence of the Trendelenburg sign to determine the upper limit of cup position from the standpoint of hip-abductor strength. Results Of the 200 hips, 20 (10%) showed a positive Trendelenburg sign. There were no statistically significant differences between parameters (the centre of rotation, femoral offset, abductor lever arm) regarding the presence of the Trendelenburg sign except for age at surgery. Patients with a positive Trendelenburg sign were significantly older (64.1 ± 9.4 years) than those with a negative Trendelenburg sign (58.8 ± 7.7 years) (P = 0.01). Conclusions Our findings indicate that a high centre of hip rotation of up to approximately 30 mm from the inter-teardrop line is a feasible option for patients with DDH from the standpoint of hip-abductor strength if stems are used that allow the restoration of femoral offset and the abductor lever arm.
Subject
Orthopedics and Sports Medicine,Surgery
Cited by
16 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献