The Accuracy of Ultrasound Volume Flow Measurements in the Complex Flow Setting of a Forearm Vascular Access

Author:

Van Canneyt Koen1,Swillens Abigail1,Lovstakken Lasse2,Antiga Luca3,Verdonck Pascal1,Segers Patrick1

Affiliation:

1. IBiTech-bioMMeda, Ghent University, Ghent - Belgium

2. Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim - Norway

3. Orobix s.r.l., Bergamo - Italy

Abstract

Purpose Maturation of an arterio-venous fistula (AVF) frequently fails, with low post-operative fistula flow as a prognostic marker for this event. As pulsed wave Doppler (PWD) is commonly used to assess volume flow, we studied the accuracy of this measurement in the setting of a radio-cephalic AVF. Methods As in-vivo validation of fistula flow measurements is cumbersome, we performed simulations, integrating computational fluid dynamics with an ultrasound (US) simulator. Flow in the arm was calculated, based on a patient-specific model of the arm vasculature pre and post AVF creation. Raw ultrasound signals were subsequently simulated, from which Doppler spectra were calculated in both a proximal and a distal location. Results The velocity component in the direction of the PWD-US beam (vPWD), in a centered, small, sample volume, can be captured accurately using PWD spectrum mean-tracking (maximum bias [mB] 8.1%). However, when deriving flow rate from these measurements, a high degree of inaccuracy occurs. First, the angle-correction of vPWD towards the velocity along the axis of the vessel is largely influenced by the radial velocity components in the complex flow field (mB=16.3%). Second, the largest error is introduced when transferring the centerline velocity to the cross-sectional mean velocity without any knowledge of the flow profile (mB=97.7%). Conclusions In the setting of a forearm AVF, flow estimates based on PWD are hampered by the complex flow patterns. Overall, flow estimation based on centerline measurement, analyzed by mean-tracking of the RF-spectral estimates, under the assumption of a parabolic flow profile, appeared to provide the most reasonable values.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3