Comparison of Fluid Dynamics Variations Between Chimney and Fenestrated Endografts for Pararenal Aneurysms Repair: A Patient Specific Computational Study as Motivation for Clinical Decision-Making

Author:

Moulakakis Konstantinos G.1ORCID,Kakisis John1,Gonidaki Eleni2,Lazaris Andreas M.1,Tsangaris Sokrates2,Geroulakos George1,Manopoulos Christos2

Affiliation:

1. Department of Vascular Surgery, Medical School, National and Kapodistrian University of Athens, Attikon University Hospital, Athens, Greece

2. Biofluid Mechanics and Biomedical Engineering Laboratory, Fluids Section, School of Mechanical Engineering, National Technical University of Athens, Greece

Abstract

Background-Aim: Limited data exist concerning the fluid dynamic changes induced by endovascular aortic repair with fenestrated and chimney graft modalities in pararenal aneurysms. We aimed to investigate and compare the wall shear stress (WSS) and flow dynamics for the branch vessels before and after endovascular aortic repair with fenestrated and chimney techniques. Methods: Modeling was done for patient specific pararenal aortic aneurysms employing fenestrated and chimney grafts (Materialise Mimics 10.0) before and after the endovascular procedure, using computed tomography scans of patients. Surface and spatial grids were created using the ANSYS CFD meshing software 2019 R2. Assessment of blood flow, streamlines, and WSS before and after aneurysm repair was performed. Results: The endovascular repair with chimney grafts leaded to a 43% to 53% reduction in perfusion in renal arteries. In fenestrated reconstruction, we observed a 15% reduced perfusion in both renal arteries. In both cases, we observed a decrease in the recirculation phenomena of the aorta after endovascular repair. Concerning the grafts of the renal arteries, we observed in both the transverse and longitudinal axes low WSS regions with simultaneous recirculation of the flow 1 cm distal to the ostium sites in both aortic graft models. High WSS regions appeared in the sites of ostium. Conclusions: We observed reduced renal perfusion in chimney grafts compared to fenestrated grafts, probably caused by the long and kinked characteristics of these devices.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3