Microseparation and Stripe Wear in Alumina-On-Alumina Hip Implants

Author:

Affatato Saverio1,Traina Francesco12,Toni Aldo12

Affiliation:

1. Medical Technology Laboratory, Rizzoli Orthopedic Institute, Bologna - Italy

2. Orthopedics, Traumatology, Hip and Knee Prosthetic and Revision Surgery, Rizzoli Orthopedic Institute, Bologna - Italy

Abstract

The combination of materials that still has highest wear resistance for total hip replacement is ceramic-on-ceramic. However, brittleness is a major concern for ceramics: in vivo and in vitro studies on ceramic hip prostheses correlate microseparation with hip noise, ceramic wear, or ceramic liner damage. Ceramic microseparation can lead to edge load, ceramic head wear, and squeaking. The aim of this in vitro study was to investigate whether different angles of inclination influence the wear pattern of alumina-on-alumina hip joints with micro-separation during the swing phase. We also evaluated the wear rate obtained from this in vitro investigation with retrieval specimens obtained at 13 years' mean follow-up. The study was performed using a 12-station hip joint wear simulator (Shore Western, Monrovia, CA, USA) under bovine calf serum used as lubricant. Wear was evaluated by the gravimetric method and the test length was set at two million cycles. After two million cycles, a volumetric loss of 0.11 ±0.03 mm3 and 0.12 ±0.06 mm3 was observed, respectively, for 23° and 63° angles of inclination. In particular, the results obtained in this work revealed an increase of about 12-fold compared to previous results without microseparation conditions. No significant differences were observed between the two different inclinations on the wear patterns of the acetabular cups with a level of significance of α = 0.5. The location and general shape of the stripes wear were similar for the retrieved and simulator balls.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 28 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Development of fused metrology methods for the analysis of hip implant tribology;Surface Topography: Metrology and Properties;2023-05-03

2. Ceramic-on-Ceramic Bearings in Total Joint Arthroplasty. Part 1;Visnyk Ortopedii Travmatologii Protezuvannia;2022-08-31

3. Tribocorrosion-resistant biofunctionalized Ti-Al2O3 composites;Surface and Coatings Technology;2021-08

4. Arthroscopic evaluation and treatment of a squeaking hip. A case report;BMC Musculoskeletal Disorders;2020-12

5. Clinical and surgical aspects of medical materials’ biocompatibility;Handbook of Biomaterials Biocompatibility;2020