Evaluation of a commercial in-house test kit for the semi-quantitative assessment of microalbuminuria in cats

Author:

Mardell Ellie J.1,Sparkes Andrew H.2

Affiliation:

1. Nantwich Veterinary Group, Crewe Road End, Nantwich, Cheshire CW5 2SF, UK

2. Centre for Small Animal Studies, Animal Health Trust, Lanwades Park, Kentford, Newmarket, Suffolk IP33 3XU, UK

Abstract

Proteinuria was assessed in 100 randomly selected sick cats and 22 healthy cats by means of the urine protein:creatinine ratio, a traditional urine ‘dipstick’ and a commercial ELISA-based dipstick designed to detect microalbuminuria (MA) semi-quantitatively. In addition the repeatability and reproducibility of the MA test was assessed by comparing results of five replicate tests of 26 urine samples, interpreted by two different readers. Discrepancies existed in the replicate test result in 23 and 27% of the samples examined by reader 1 and 2, respectively, and on several occasions this discrepancy was between whether the sample was ‘positive’ or ‘negative’ for MA. The inter-reader agreement was good ( κ=0.75), but again discrepancies were noted and part of the reason for these problems appeared to be the necessary subjectivity in the interpretation of colour changes when reading test results. Proteinuria was significantly ( P≤0.014) more prevalent in the sick than the healthy cats with 36 and 9%, respectively, having detectable MA, 34 and 5%, respectively, having a urine protein to creatinine (UPC) ratio >0.5, and 84 and 9%, respectively, having positive urine protein dipstick analysis. There was a moderate significant correlation between UPC ratio and MA concentrations ( rs=0.68, P<0.0001). While 13/87 cats with a UPC ratio ≤0.5 had positive MA results, 10/84 cats with negative MA results had a UPC ratio >0.5, and none of these had evidence of lower urinary tract disease. This study confirmed that MA and proteinuria are commonly seen in cats with a variety of diseases, but they are not necessarily both elevated, and the UPC ratio can be elevated without an increase in MA results. Furthermore, some repeatability problems were demonstrated with the semi-quantitative MA test. These findings demonstrate that the semi-quantitative MA test should not be relied on as the sole determinant of proteinuria.

Publisher

SAGE Publications

Subject

Small Animals

Cited by 21 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3