Validation of an electrophoretic method to detect albuminuria in cats

Author:

Ferlizza Enea1,Dondi Francesco1,Andreani Giulia1,Bucci Diego1,Archer Joy2,Isani Gloria1

Affiliation:

1. Department of Veterinary Medical Sciences, University of Bologna, Ozzano, Italy

2. Department of Veterinary Medicine, University of Cambridge, Cambridge, UK

Abstract

Objectives The aims of this study were to validate a semi-automated high-resolution electrophoretic technique to quantify urinary albumin in healthy and diseased cats, and to evaluate its diagnostic performance in cases of proteinuria and renal diseases. Methods Urine samples were collected from 88 cats (healthy; chronic kidney disease [CKD]; lower urinary tract disease [LUTD]; non-urinary tract diseases [OTHER]). Urine samples were routinely analysed and high-resolution electrophoresis (HRE) was performed. Within-assay and between-assay variability, linearity, accuracy, recovery and the lowest detectable and quantifiable bands were calculated. Receiver operating curve (ROC) analysis was also performed. Results All coefficients of variation were <10%, percentage recovery was between 97% and 109% with a high linearity (r = 0.99). HRE allowed the visualisation of a faint band of albumin and a diffused band between alpha and beta zones in healthy cats, while profiles from diseased cats were variable. Albumin (mg/dl) and urine albumin:creatinine ratio (UAC) were significantly ( P <0.05) different between healthy and diseased cats. After ROC analysis, UAC values of 0.035 and 0.074 had a high sensitivity and high specificity, respectively, to classify proteinuria and identify borderline proteinuric cats. Moreover, a UAC of 0.017 had a high sensitivity in distinguishing between healthy and diseased cats. However, UAC was not able to distinguish between renal (CKD) and non-renal diseases (LUTD/OTHER), probably owing to the pathophysiology of CKD in cats, which is characterised by low-grade proteinuria and less glomerular involvement than in dogs. Conclusions and relevance HRE is an accurate and precise method that could be used to measure albuminuria in cats. UAC was useful to correctly classify proteinuria and to discriminate between healthy and diseased cats. HRE might also provide additional information on urine proteins with a profile of all proteins (albumin and globulins) to aid clinicians in the diagnosis of diseases characterised by proteinuria.

Funder

Università di Bologna

Publisher

SAGE Publications

Subject

Small Animals

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3