Monte Carlo calculation of the dose distributions of two 106Ru eye applicators

Author:

Sánchez-Reyes Alberto,Tello Juan José,Guix Benjamín,Salvat Francesc

Publisher

Elsevier BV

Subject

Radiology, Nuclear Medicine and imaging,Oncology,Hematology

Reference17 articles.

1. Monte Carlo techniques in medical radiation physics;Andreo;Phys. Med. Biol.,1991

2. Enucleation vs. cobalt plaque radiotherapy for malignant melanomas of the choroid and ciliary body;Augsburger;Arch. Ophthalmol.,1986

3. PENELOPE: an algorithm for Monte Carlo simulation of the penetration and energy loss of electrons and positrons in matter;Baró;Nucl. Instrum. Methods B,1995

4. Berger MJ, Seltzer SM. In: Jenkins TM, Nelson WR, Rindi R, editors. Monte Carlo transport of electrons and photons, Chapters 7 and 8. New York: Plenum, 1988.

5. Determination of the dose distribution of an ophthalmic Ru-106 eye applicator with TLDs and eye phantom;Binder;Rad. Prot. Dosimet.,1990

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3