Monte Carlo simulation of tilted contact plaque brachytherapy placement for juxtapapillary retinoblastoma

Author:

Nakamura Satoshi,Murakami NaoyaORCID,Suzuki Shigenobu,Ito Kimiteru,Takemori Mihiro,Nakayama Hiroki,Kaga Keita,Chiba Takahito,Iijima Kotaro,Takahashi Kana,Goka Tomonori,Itami Jun,Okamoto Hiroyuki,Igaki Hiroshi

Abstract

Abstract Background The 106-Ruthenium contact plaque applicator is utilized for the treatment of intraocular tumor within a thickness of less than 6 mm. If anything obstructs the placement of the plaque applicator, the treatment is generally difficult because the applicator has to be temporarily located just on the opposite side of the retinal tumor. Furthermore, the plaque applicator edge of approximately 1 mm does not contain 106Ru, estimating the delivered radiation dose for eccentric tumor is challenging because the lateral dose profile is inadequately provided by the manufacture’s certification. This study aims to simulate tumor coverage of the tilted applicator placement for treating an infant with juxtapapillary retinoblastoma and to achieve the effective treatment. Case presentation We present an infant with retinoblastoma whose tumor involved macular and was invading just temporal side of the optic disc. Additionally, posterior staphyloma was induced by a series of previous treatments, making it more difficult to treat the standard plaque placement. Thus, the applicator type of CCA was intentionally tilted to the eyeball and the distance between the posterior edge of the applicator and the eyeball had to be then equal to or more than 2 mm based on the dose distribution of the applicator calculated using Monte Carlo simulation to minimize damage to surrounding tissues while covering the tumor. It was then comparable to the certification and previous reports. Based on the acquired dose distribution, the optimal placement of the applicator was derived from varying the distance between the applicator’s edge and the eyeball, and the distance was then determined to be 2 mm. In this case, the minimum dose rate in the tumor was 25.5 mGy/min, and the time required to deliver the prescribed dose was 26.2 h. Therefore, the tilted 106Ru plaque applicator placement could deliver the required dose for the treatment. The physical examination revealed no active tumor as a result of the treatment. Conclusions Optimizing the placement of the 106Ru plaque applicator, it was possible to guarantee that the prescribed dose will be delivered to the tumor even if the standard placement is not possible for the juxtapapillary tumor.

Funder

Japan Society for the Promotion of Science

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Oncology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Antineoplastics;Reactions Weekly;2023-01-07

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3